Flash Point Close Cup Hinotek

The Flash Point Close Cup is an essential instrument used to determine the flash point of petroleum products. Manufactured in accordance with the standards set by GB/T 261-2008 and ASTM D93, this device utilizes the Pensky-Martens closed cup method to accurately measure the flash point. The determination of a product’s flash point is crucial for assessing its flammability and safety, particularly in industries dealing with fuel, chemicals, and oils

Description

Flash Point Close Cup

The Flash Point Close Cup is an essential instrument used to determine the flash point of petroleum products. Manufactured in accordance with the standards set by GB/T 261-2008 and ASTM D93, this device utilizes the Pensky-Martens closed cup method to accurately measure the flash point. The determination of a product’s flash point is crucial for assessing its flammability and safety, particularly in industries dealing with fuel, chemicals, and oils.

FLASH POINT CLOSE CUP

I. Main technical features

1. Single chip microcomputer control technique.LCD screen displays.English man-machine interaction interface.The heating power is continuously step-less adjustable.The rate of heating up is exact.Easy setting for parameters.
2. The LCD screen has prompting menu, prompting input operation interface.It shows the set parameters, real-time temperatures, and other test parameters.Press the “record” button when the flash point appears.The screen will show and reserve the flash point.
3. The structure is a new design and small.Stainless steel table-board looks clean and beautiful.It can be used as long as equipped with gas or other civilian fuels.It is easy to use and test results exactly.

II. Main technical specifications

1. Power supply: AC( 220±10% )V, 50Hz.
2. Heating device: (1) The furnace is silicon carbide material. Power is 600W.
                                (2) The heating power is adjustable from 0 W to 600W.
3. Heating rate:Procedure A:  (5~6)℃/min, Procedure B:(1~1.6)℃/min.
                                                    Automatically controlled
4. Stirring device:(1)Stirring motor:  BYGH101 stepping motor
                              (2) Driving mode: flexible shaft
                              (3) Shaft size:  8mm×40mm
5. Stirring rate:Procedure A:  (90~120)RPM, Procedure B: (250±10)RPM
6. Igniting device: (1) Igniting source: gas(or other civilian fuels,the same below)
                               (2) Electric ignition. Gas flame diameter:3.2mm~4.8mm
7. Temperature testing probe: RTD, PT100
8. Ambient temperature:≤ 35℃
9. Relative humidity:≤ 85%
10.Maximum power consumption: 650W

 

View More Product “Portable Spectrofotometer”

Contact Us: 081281557024

 

Reviews

There are no reviews yet.

Be the first to review “Flash Point Close Cup Hinotek”